Semi-insulated ring network cabinet: HXGN15-12
This product features a semi-insulated design, with busbars and certain high-voltage live components encased in insulating materials to effectively reduce phase-to-phase and ground distances, resulting in a compact structure. The cabinet is typically constructed from high-quality steel plates, ensuring robustness and reliability. The core switch unit can be flexibly configured with load switches, load switch-fuse combinations, or vacuum circuit breakers, equipped with comprehensive "five-prevention" interlock functions to ensure operational safety. Standard configurations support rated current switching of 630A and transfer current closing, with short-circuit withstand current reaching 20kA/3s.
Project |
Unit |
numerical value |
Rated Voltage |
KV |
12 |
Rated Frequency |
Hz |
50 |
The rated current of the main busbar and the maximum rated current of the fuse |
A |
630,125 |
rated short time withstand current of main circuit and grounding circuit |
KA/S |
20,3 |
Main circuit and ground return rated peak current tolerance |
KA |
50 |
rated short-circuit closing current of main circuit and grounding circuit |
KA |
50 |
Number of times the load switch has been fully opened at full capacity |
number of times |
100 |
current of fuse breaking |
KA |
31.5,40 |
rated closed-circuit breaking current |
A |
630 |
rated transfer current |
A |
1600 |
mechanical life |
number of times |
2000 |
1min Power Frequency Withstand Voltage (Peak) Relative to Earth, Isolating Switch |
KV |
42,48 |
Lightning Impulse Withstand Voltage (Peak) Relative to Earth, Isolating Switch |
KV |
75,85 |
Secondary circuit withstand voltage at power frequency for 1 minute |
KV |
2 |
levels of protection |
- |
IP3X |
Project |
Unit |
numerical value |
Rated Voltage |
KV |
24 |
Rated Frequency |
Hz |
50/60 |
Lightning Impulse Withstand Voltage (Peak) |
KV |
Phase-to-phase: 60; Isolation break: 79 |
1min Power Frequency Withstand Voltage(effective value ) |
KV |
Phase-to-phase:125; Isolation break: 145 |
Auxiliary control circuit withstand voltage at power frequency |
V |
200 |
Rated Current |
A |
630,1250,1600,2000,2500,3150 |
Rated Short-Circuit Interrupting Current |
KA |
20/31.5 |
Rated Short-Circuit Closing Current (Peak) |
KA |
50/80 |
Rated Short-Time Withstand Current |
KA |
20/31.5 |
Rated Peak Withstand Current |
KA |
50/80 |
Auxiliary Control Circuit Rated Voltage |
V |
DC or AC 110/220 |
Protection Degree |
- |
IP4X(The circuit breaker room door is open or the compartment is IP2X.)IP4X |
External Dimensions (Width×Depth×Height) |
MM |
800×1810×2380/1000×1810×2380 |
Weight |
Kg |
840-1440 |
Operating Conditions
The ring network cabinet is an ideal choice for the ring network connection and terminal power supply of medium voltage distribution network, which has the characteristics of modular design, easy installation and maintenance, safe and stable operation and high cost performance, and effectively improves the reliability and flexibility of power supply system.
Request A Quote